5%) to the second one (12.8%). Conclusion: Routine use of IV heparin following digital replantation and revascularization is not warranted. Surgical technique and
type of injury remains the most important predictors for success in selleck these complex procedures. © 2011 Wiley-Liss, Inc. Microsurgery 2011. “
“The patient was a 62-year-old man with chief complaints of pharyngeal pain and dysphagia. He was diagnosed with pyriform sinus poorly differentiated squamous cell carcinoma T3N0M0 (Stage II) and underwent partial laryngopharyngectomy, lymphadenectomy in the right neck, tracheostomy, and reconstruction of the larynx and aryepiglottic fold with a free radial forearm flap and the associated vascularized palmaris longus tendon. No particular problems occurred after surgery, and swallowing and articulation functions were successfully recovered. A free jejunum transfer is the first choice for reconstruction
of a defect after partial hypopharyngectomy, but reconstruction of the supracricoid complex structure of the larynx using a free jejunum transfer after partial laryngopharyngectomy may lead to aspiration of intestinal fluids. In this case, we performed functional reconstruction of the laryngopharyngeal defect using a free radial forearm flap including a vascularized tendon of the palmaris longus, and satisfactory postoperative function was achieved. We believe that the key to successful functional recovery after partial laryngopharyngectomy is establishment of the three-dimensional complex structure of the arytenoid and aryepiglottic fold. © 2011 Wiley Periodicals, Inc. Microsurgery, 2012. “
“The purpose of this study is to evaluate Selleck Mitomycin C the use of the venous anastomotic Flow Coupler in monitoring free flaps used for breast reconstruction in a consecutive series of patients. Retrospective data were 5-Fluoracil purchase collected on patients undergoing free flap breast reconstruction from May 2012 to March 2014. The venous anastomotic Flow Coupler was used in the first 85 flaps and a non-flow
Coupler with clinical and external Doppler monitoring alone in the subsequent 34 flaps. Data collected included patient age, BMI, prior radiation, flap type, intra- and postoperative Flow Coupler events, along with rates of flap take back, salvage, and failure. Proportion data were compiled and statistically analyzed. One hundred nineteen consecutive abdominal based breast reconstruction free flaps were performed. The overall flap failure rate was 4.2% (4.7% Flow Coupler; 2.9% in non-flow Coupler; P = 1.0). The Flow Coupler demonstrated 100% sensitivity in the intra- and postoperative settings. A positive predictive value of 36% was noted intraoperatively which was significantly higher compared to the non-flow Coupler group (P = 0.015). Vessel thrombosis occurred in 17.6% of Flow Coupler flaps, which was significantly higher when compared to the non-flow Coupler (2.9%; P = 0.038). The Flow Coupler is a sensitive method to confirm patency of a microsurgical anastomosis.